Condo Heat Pumps aka Water Source Heat Pumps typically fail due to 5 common reasons. Heat Pumps have strict operation requirements during heating or air conditioning seasons. Failure to satisfy these requirement will disrupt heat pump operation in winter months. By understanding these requirements and taking preventative measures, residents & property managers can ensure optimal performance throughout the cold season.
What Are The 5 Most Common Reasons Condo Heat Pumps Fail During Winter?
Call Us Now (416) 736-7001 to Speak With a Live Agent
Contact Us Today!1. Low Water Temperature
Low supply water temperature can hinder the heat pump’s ability to extract enough heat from the water source. This can occur when the building water supply isn’t adequately heated or if there are problems with the boiler or the heat exchangers in the building. To address this, it’s important to ensure that the water source supplies sufficiently heated water to the heat pump loop lines. Heat Pump water circulation is typically controlled & supervised by the building mechanical contractor. In the event of a building problem, a certified in-suite HVAC company needs to send a formal report to your property manager to escalate it to the property manager.
Condo Heat Pump Water Temperature Toronto
2. Inadequate Waterflow
Low water flow or inconsistent flow can cause interruptions, shutdowns and resets for the water source heat pumps. Condo Water Cooled Heat Pumps normally require 2 to 3 GPM per TON for proper operation. If the base building pumps fail to provide adequate water flow, then the in-suite heat pump systems normally fail due to low pressure. A certified mechanic should verify water flow to ensure this requirement is satisfied before making changes to the heat pump system.Â
Condo Heat Pump Water Flow Toronto
3. Airflow Restriction
Heat pumps may struggle to operate if the return air grille is blocked due to a dirty filter, or obstructions such as sofa or bed. Condo Heat Pumps are recommended to have 2 to 3 ft clearance for optimal output. We also advise residents to replace existing filters every 4 months. Learn about different filters you can use in your condo.
Condo Heat Pump Dirty filter
4. Electrical & Control Malfunction
Electrical Components within the water source heat pump, like the thermostat, switches, capacitors, sensors, time delay relay, relays, transformers, fan motor, or control board, could also the root cause for malfunctioning heat pumps in winter. These problems are required to be addressed right away. Resetting your heat pump from the breaker panel on a regular basis may damage or reduce the chassis lifespan. Â Â
Condo Heat Pump Electrical Problem
5. Heat Pump Mechanical Problems
If your condo heat pump is struggling to provide sufficient heat during winter, there might be a problem with the refrigeration compartment of the chassis. Restriction, leaks and Incorrect Refrigerant charges are common causes of mechanical failure in condo heat pump systems. Ensuring the heat pump is appropriately sized and installed based on the specific requirements is crucial for optimal performance.
Condo Heat Pump Chassis Problem
Schedule an Inspection – Toronto Condo Heat Pump Service Center
Call Us Now (416) 736-7001 to Speak With a Live Agent
Contact Us Today!Condo Heat Pumps aka Water Source Heat Pumps have different requirements during heating or air conditioning seasons. By understanding these requirements and taking preventative measures, residents & property managers can ensure optimal performance throughout the cold season.